GraphicAir Model A200H-D/A100H-D

Printable PDF Specs
FEATURES
These units exhaust air via flexi-duct externally to atmosphere.
Comprising: Particulate filter to 5 microns - Centrifugal blower(s), brushless external rotor motor type (Model A100H-D has two blowers), UL, VDE and CSA approved - Sealed electrical wiring and switch, downstream of filters - 2 metre x 100mm flexi-duct (A100H-D uses two flexi-ducts) - All Steel construction finished in dove grey - Hood enclosure workstation.
| Dimensions | A200H-D | A100H-D |
|---|---|---|
| H x W x D | 600 x 680 x 530 | 740 x 960 x 720 |
APPLICATIONS
General-purpose workstation for aerosol spray filtration and fine particulate, fume and vapour extraction.
Art & Graphics
For applying aerosol adhesives, lacquers fixatives and airbrush sprays to artwork placed onto a standard A2 (A200H-D) or A1 (A100H-D) drawing board within the hood enclosure. Boards fit at an angle for efficient overspray capture and ease of use.
Hobbies, Modelling & Crafts
Accommodates prototypes, models, ceramics, PCBs etc, placed onto the hood base to be sprayed, soldered, cleaned, glued, moulded, sanded, etc.
Optional accessories available include Part Nos. P4010 and P4020 clear polycarbonate panel for reduced hood face size and higher air velocity. P4010L and P4020L polycarbonate panel complete with fluorescent hood lighting unit.
These units are designed for immediate operator protection whereby large particulates (> 5 microns) are filtered and fine particulates (< 5 microns) together with gases, vapours and fumes within the hood are exhausted to atmosphere via the flexi-duct.
| MODEL NO | FAN MOTOR * | AVERAGE AIR VELOCITY |
AVERAGE AIR VELOCITY AT HOOD FACE |
|---|---|---|---|
| A200H-D | 230V 50Hz 40W | 0.60m/sec 118ft/min | 0.25 m/sec 49ft/min |
| A100H-D | 230V 50Hz 80W | 0.60m/sec 118ft/min | 0.30 m/sec 59ft/min |
* 110V 60Hz available if required.
Detailed Dimensions:- A200H = A, A100H = B
FILTRATION
The particulate filter (Ref 4) is a three stage, graduated fibre filter. The open structure of the first stage discourages surface loading and promotes depth filtration, ensuring a high dust holding capacity and reducing resistance to airflow. The denser backing filter and final scrim material provides finer filtration to 5 micron. NB: Spray particulate size varies from 10 to 20 microns. Pollen size averages 15 microns.

| Ref No | Description | Part Number |
|
|---|---|---|---|
| A200H-D | A100H-D | ||
| 1 | Fan (Blower) and 2m Flexi duct (x2 for A100H-D) | ||
| 2 | Handwheels M6 x 4 | P5004 | P5004 |
| 3 | Fan Housing/Mounting | P1001-D | P1002-D |
| 4 | Particulate (Intake) Filter to 5 micron | IFA3 | IFA2 |
| 6 | Hooded Enclosure | P4001 | P4002 |